Lapp oil flex © Solar XLS -R T 2x6 BK/RD - Lose

Stock: Small amount
Product number: 8-01-006280
EAN: 0797337909983
google-icon

Google Reviews

4.9

132 Reviews

€4.15*

Oilflex © Solar XLS -R T BK/RD solar cable - essential product features:

1. Oilflex® Solar XLS-R T are halogen-free, double-insulated and networked twin lines for constant use outdoors. These lines are used for photovoltaic system construction to wire the individual solar modules with each other and for wiring with the inverter

2. Building data --- conductor: Fine-wound strands made of tinned Cu wires, in accordance with IEC 60228, class 5 --- vein isolation: temperature-resistant and halogen-free co-polyolefin, radiation-networked Pair colors: black/red --- outdoor coat: external and halfogen-free Co-polymer, radiation networked outer coat color: black

3. Special features for the networked compound are in addition to the extended temperature range, very good values ​​regarding UV, ozone and weather resistance as well as abrasion resistance. They are used to wire solar modules with each other, as well as to connect the individual module series and the inverter.

The specified price applies per ongoing meter!

Electrical Properties

Nominal voltage U0/U according to VDE: AC 600/1000 V/DC 900/1500 V
Highly permissible DC voltage: 1.8 KV DC (head/conductor, non -grounded system)
Test voltage AC 6.5 kV voltage strength tests according to EN 50395

Thermal properties

Temperature range fixed: -40 ° C to +100 ° C max.
Short -circuit temperature +200 ° C
Flexible laying temperature: max. -25 ° C
Themic lifespan in accordance with EN 60216-2
Heat pressure resistance in accordance with EN 60811-3-1
Wet heat test according to EN 60068-2-78 with 85% humidity

Mechanical properties

Minimum bending radius occasionally moved: 15 x cable diameter
Set: 5 x cable diameter
Dynamic penetration: according to the requirement profile AK 411.2.3 Appendix F
Further tearing resistance: according to the requirement profile AK 411.2.3 Appendix G
Examination of the isolation and mantle break resistance as well as stretching: in accordance with EN 60811
Chemical properties

Ozone resistance: in accordance with EN 50396 Part 8.1.3 Procedure B
Weather / UV resistance according to HD 605 / A1
Fire behavior flamed according to IEC 60332-1-2
Halogen freedom according to IEC 60754-1
Acid and lye resistance in accordance with EN 60811-2-1 (oxalic acid and sodium hydroxide solution)
EC guidelines

The lines are compliant to the EC guidelines 2006/95/EC (Lower Voltage Directive) and 2002/95/EG and 2011/65/EG (Rohs, restriction of the use of certain dangerous substances).

Laying in the ground

Solar lines can generally be laid in the ground in the ground for laying the earth if it is ensured that there is no permanent contact with water and waterlogging is removed safely. The laying of the lines and correct execution of the cable ditch must correspond to VDE 0100 part 520 or comparable standards.

 

data sheet

Generally
item number 8-01-006280
Manufacturer part number 0023986
Product Solar cable
Manufacturer Lapp cable
Characteristics Fire behavior (flamed according to IEC 60332-1-2)
material copper
Area of ​​operating environmental temperature Stated: -40 ° C to +100 ° C max.
Leadership Class 5 / IEC 60228 Cl.5
Copper content 115.2kg/km
Ladder cross -section (mm²) 6 mm²
Test voltage AC 6500 V
Wire colors Black red
Number of veins 2
classification EIM 5.0 Class description: Flexible line, EIM 5.0 Class ID: EC001578
Dimensions (LXBXH) (WXH) 11.9 x 5.8 mm
Weight 174kg/km
EAN 0797337909983

0 of 0 reviews

Leave a review!