6227498270893
Siemens 5SU1356-6KK10 RCCB 2-pole 10A 0.03A 230V
Technical details
Frequency
50Hz
Connectable conductor cross section stranded
0.75 | 35.0
Number of poles (total)
2
Energy Limit Class
3
Rated breaking capacity according to EN 61009
6.0
Rated breaking capacity according to IEC 60947-2
15.0
Rated switching capacity Icn according to EN 61009-1
6.0
Type of stress
AC
Width in pitch units
2
False trip protection
yes
Number of fused poles
1
Rated residual current
0.03
Suitable for flush-mount installation
yes
degree of protection (IP)
IP20
Rated voltage
230
Rated insulation voltage Ui
264
Rated impulse withstand voltage Uimp
4.0
Rated current
10
surge current resistance
1.0
Release characteristic
B
Switching neutral conductor
yes
With locking device
yes
Overvoltage Category
3
degree of pollution
2
Ambient temperature during operation
-25 | 55
Installation depth
70.0
Connectable conductor cross-section, solid
0.75 | 35.0
Delivery time: 1-3 working days
Small amount
73540301
Spelsberg AK 03 small distributor, 3 modular widths, 1 row, IP65
Safe - Thanks to the high degree of protection IP65 and the robust, halogen-free design, safe operation is guaranteed even under harsh industrial environmental conditions.
Material:
Box: polystyrene, light gray similar to RAL 7035
Lid: polystyrene, light gray similar to RAL 7035
Hinged window: polycarbonate, transparent
Seal: Polyurethane
Cover screw: Polyamide 6, glass fiber reinforced
More properties:
Color: grey
Protection class: IP65 - according to EN 60529 / DIN VDE 0470-1
Number of pitch units: 3
Heavy metal free
PVC-free
Silicone-free
sealable
Impact strength: IK07 according to DIN EN 5012 / VDE 0470 part 100
Cover screw torque: 1.2 N m
Environmental conditions:
Ambient temp. (minimum): -25°C
Ambient temp. (maximum): 40°C
Ambient temp. (24 hours): 35°C
Max. rel. Humidity at 25°C (short term): 95%
Max. rel. Humidity at 40°C: 50%
Dimensions:
Width: 100mm
Length: 150mm
Height: 96mm
Internal height: 95mm
?Delivery time: immediately from stock
Small amount
010002110
PHILIPPI shore connection unit LAE 211
Shore connection unit for mains power takeover 230V/50Hz with Schuko socket. Mains control lamp shows mains status. Internal mains connection directly to the terminals of the RCBO circuit breaker, cable entry with PG screw connection. Splash-proof all-plastic housing with hinged lid. Degree of protection IPX4.
Power indicator light
RCBO circuit breaker 16A/0.03A 2-pole
Dimensions: W 97 x H 246 x D 97mm
Small amount
010000231
Philippi LAR on-board network control for the AC network
The network control panel LAR shows the electrically correct connection of the AC-BRONZ network to the AC land network: Green light: Everything connected correctly, red light: phase (L) and zero conductor (s) are exchanged. Measuring error current 1.4 mA, not suitable for AC networks without protective conductor, since no error detection is possible here.The consumer supplies are connected via flat stains 6.3mm on the back.The panel is to be installed in such a way that the back is only accessible and covered with tools.The installation section can be selected by 12 mm per edge smaller than the panel dimensions (81 x 28.5 mm).Dimensions: W 105 x H 52.5 x D 50 mm
Small amount
010001010
Philippi shore connection unit LAE101
Type philippi LAE 101
Shore connection unit for 230 V/50 Hz mains power supply with Schuko socket for the 230 V on-board supply. The power indicator light shows the correct power connection. The connection is made on the back using feed-through terminals.
Technical data:
FI/LS circuit breaker RCBO 16A/0.03A 2-pole
Dimensions W 185 x H 150 x D 100 mm
cut-out dimensions W 160 x H 125 mm
Small amount
010002300
Philippi shore connection unit LAE230
Type Philippi LAE 230
Shore connection unit for mains power takeover 230 V/50 Hz with 2-pin. RCBO circuit breaker and 2 circuit breakers.
Mains control lamp shows mains status.
Internal connections, directly on the terminals of the circuit breakers.
Cable entry with self-sealing grommet.
Waterproof plastic housing with hinged cover, protection class IP 65.
Dimensions W 160 x H 200 x D 115 mm
Small amount
111400016
Siemens 5SU1356-6KK10 FI Circuit Breaker 2-pole 10A 0.03A 230V
Einpoliger thermischer Überstromschutzschalter in Kleinbauweise. Zuverlässiges Schaltverhalten durch Sprungschaltmechanismus und unbeeinflussbare Freiauslösung. Entspricht den neuen Geräteschutzschalter-Richtlinien EN 60934. Lochauschnitt 22 x 11,3 mm. DC 48 V, AC 240 V. Nennstrombereich 2...16 A
Not in stock
010002362
Philippi Land connection unit Lae 236
6 circuits with two-pin thermal rocker protective switches 10 A for 230 V / 50 Hz. The panel must be installed in such a way that the back is only accessible and covered with tools.
ATTENTION: The panel is only permissible if there is a pre-protection with a RCBO (FI/LS) circuit breaker.
Dimensions: W 105 x H 210 x D 70 mm
Small amount
010001130
Philippi Shore Connection Unit LAE113
Type Philippi LAE 113
Shore connection unit for mains power takeover 230 V/50 Hz with RCBO (FI/LS) circuit breaker and Schuko socket for the 230 V on-board supply.
Mains indicator lights indicate correct mains connection.
3 double-pole circuit breakers (10 A) for sockets, boiler and charger.
Dimensions: W 260 x H 185 x D 100 mm
Small amount
010002201
PHILIPPI shore connection unit LAE 220
Shore connection unit for mains power takeover 230V/50Hz. Mains control lamp shows mains status. Internal mains connection directly to the terminals of the RCBO circuit breaker, cable entry with cable gland. Plastic housing IP 65 with hinged cover. RCBO (FI/LS) circuit breaker: 16A/0.03A 2-pole Dimensions: W 80 x H 150 x D 97 mm