AC Accessories
- News
- Complete Systems
- Batteries
- Electronics
- Installation
- Expansion
- Solar Technology
- Marken
Filter
–
Available (more than 10)
REL200200100
Victron Energy Meter EM24 - 3 phase - Max 65a/phase Ethernet
The Energy Meter EM24 from Victron Energy (MPN Rel200200100) is a three-phase energy counter with a maximum of 65a per phase. It is used in the house connection/counter box to measure the services on all three phases.
The energy meter can be used as:
Grid knife and is used as a tax input for an ESS system
Measurement device for the performance of a PV inverter
Measurement device for the performance of an alternating current unit
For all uses mentioned above, the measuring device should be connected to the local network so that the GX device can achieve it.
Note on GX firmware versions
To support the Ethernet EM24 measuring devices, Venus 2.60 is the minimum firmware required on the GX device.
Scope of delivery:
1x Victron Energy Meter EM24 Rel200200100
Ambient temperature
-25 ° C - +55 ° C
EAN
8719076051268
Manufacturer part number
Rel200200100
Weight
0.44 kg
Dimensions (LXBXH)
120 x 100 x 70 mm
Manufacturer
Victron Energy
Display
permanently integrated LCD display
Available (more than 10)
REL300300000
Victron electricity meter ET340 3-phase max 65a/phase
The Victron ET340 (MPN Rel300300000) is a 3-phase electricity meter that is designed for a maximum current of 65a per phase.
The ET340 electricity meter can be used for four different applications:
Electricity meter and tax input in an ESS (home storage system) in connection with the Color Control GX and a Victron inverter
Electricity measurement at the output of a PV inverter
Electricity measurement at the output of an AC unit
Wiring and connection of the ET340
There are two options in its wiring. On the one hand, the direct connection, via the RS485 to USB interface with 1.8m or 5m cable or alternatively the wireless connection via ZigBee.
Scope of delivery:
1x VICTRON Rel300300000 ET340 3-phase power meter 65a/phase
1x operating instructions
Weight
0.23 kg
Manufacturer
Victron Energy
guarantee
5 years of manufacturer's guarantee
Available (more than 10)
REL200300100
Victron 3-Phase Energy Meter Smart Meter VM-3P75CT
Dreiphasen-Energiezähler mit Ethernet- und VE.Can-KommunikationsanschlüssenDer Victron VM-3P75CT Energiezähler ist ein Standardgerät zur Messung der Leistung und Energie in Einzel- und Dreiphasenanwendungen, beispielsweise im Verteilerschrank oder zur Messung der Leistung eines PV-Wechselrichters, eines AC-Generators oder der Leistung eines Wechselrichters und Wechselrichter-/Ladegeräts.Hohe AktualisierungsrateDurch Berechnung der Effektivleistungswerte für jede Phase überträgt der Energiezähler diese mit hoher Geschwindigkeit über VE.Can oder Ethernet, was zu genauereren Messungen des Leistungsverbrauchs, des Netzbezugs und des Netzrücklaufs führt, beispielsweise in einem EES-System.Der VM-3P75CT ermöglicht eine einfache EinrichtungDer Energiezähler wurde für eine einfache Integration entwickelt und funktioniert sofort (Plug & Play) als Netz-Messgerät für die meisten Systeme. Die Konfiguration (über VictronConnect) ist nur erforderlich, um die Funktion zu ändern (Netz-Messgerät, PV-Wechselrichter, AC-Generator oder AC-Last-Messgerät) sowie die manuelle IP-Konfiguration anstelle der Standardeinstellung, DHCP.Fernüberwachung von überallDie Daten werden in der VictronConnect-App, einem GX-Gerät wie dem Cerbo GX oder Ekrano GX und unserem VRM-Portal angezeigt.Mühelose Installation mit SchnappschaltstromwandlernDer VM-3P75CT verwendet Zangenmesswandler um den Strom genau zu erfassen, ohne die Verdrahtung einer bestehenden Installation ändern zu müssen.Vektor ErfassungsmethodeDer VM-3P75CT verwendet das Vektormeldeverfahren (die Vektoren jeder Phase L1, L2 und L3 werden summiert).
Small amount
EVC300400300
Victron Energy EV Charging Station - Wallbox
The new Victron high-performance EV charging station-EV Charging Station
The Victron Wallbox has three -phase and single -phase skills and delivers a maximum of 22 kW alternating current in three -phase mode or 7.3 kW in single -phase mode. Equipped with Wi-Fi communication Wi-Fi: 802.11 B/G/N for configuration and surveillance. The internal Wi-Fi module can be configured for both the initial setup and for monitoring in Access Point mode or in station mode.
The Victron charging station has a 4.3-inch LCD touchscreen for monitoring and control as well as light ring for the quick display of the device status around the charging connection to quickly determine the device status. The light ring can be programmed via the web interface in such a way that depending on the current state (separated, loaded, loaded, loaded, etc.), it shows different lighting effects. The aim is to help the user signal the current state from a distance.
Two working modes available: Manual mode for configuring the output current
The manual mode enables a configurable output current between 6-32a. The charging capacity is controlled in two ways: via the slider on the LCD touchscreen or via the website. It enables manual starting or stopping the charging process when a vehicle is connected to the charging station.
Automatic mode to ensure maximum efficiency of the PV system. It recognizes when excess energy is available and only uses this energy to charge the vehicle.
Integration with GX devices
The EV charging station can be configured and monitored via the GX screen devices and the remote console. Several options are available in the VRM portal: real-time reports, custom reports for configurable periods, extended functions such as remote firmware update.
Available (more than 10)
REL300100000
Victron electricity meter ET112 1-phase max. 100A
The Victron ET112 electricity meter 1-phase (MPN Rel300100000) for a maximum of 100A. The ET112 electricity meter can be used for four different applications:
Electricity meter and tax input in an ESS (home storage system) in connection with the Color Control GX and a Victron inverter
Electricity measurement at the output of a PV inverter
Electricity measurement at the output of an AC unit
Wiring and connection of the Ett112
There are two options in its wiring. On the one hand, the direct connection, via the RS485 to USB interface with 1.8m or 5m cable or alternatively the wireless connection via ZigBee.
Scope of delivery:
1x Victron Rel300100000 ET112 electricity meter 100a
1x operating instructions
Available (more than 10)
8-01-010710
Switching station for the US230/12 12A 2700W 230VAC network
Versatile multi -talent
Offgridtec switching stations enable you to operate 230V consumers from two different voltage sources. Typically, this is a voltage converter or the public power grid
With the priority circuit, you can determine which power source should be used preferentially - this voltage source is eliminated to the replacement current source.
The use of the highest quality relay guarantees on the one hand a particularly precise switching threshold, on the other hand, your voltage converter is optimally protected from feedback from external tension.
Recommendations
Solar island systems
Service and commercial vehicles
Mobile and caravans
Sailing boats and other watercraft
Technical specifications
Input voltage: 230VAC, 50/60Hz
Input current (max.): 12a
Output voltage: 230VAC, 50/60Hz
Performance (max.): 2700VA
Switching time: 1-2 seconds li>
Fuse: F 15A / 250V
Protection: overload, short circuit
Housing: plastic
Protection class: IP55
Inputs: screw terminals
Dimensions: (LXBXH): 120 x 120 x 58mm
Weight: 250g
Application example 1-network preliminary circuit
The 230 V AC network is connected to the input AC2 (higher priority)
This means that the battery is spared and the inverter is also protected from external tension.
Only when AC2 turns off that does the input AC1 switch to the power supply via battery and inverter
Application example 2-Inverter preliminary circuit
The inverter is connected to the input AC2 (higher priority)
This means that the electricity is primarily taken from the battery by the inverter (e.g. when using solar island systems)
The 230 V AC network is only switched on via the AC1 input
Scope of delivery:
1x switching station, grounding clamp, operating instructions, DE, GB, FR, NL, NL
Small amount
SDFI0000000
VICTRON Filax 2 Transfer CE 230V/50Hz-240V/60Hz
The ultra -fast Filax transfer switch from Victron Energy (MPN SDFI0000000) was developed to switch important or sensitive consumers such as computers, industrial control units or modern entertainment electronics from one change of alternating current to another. The main source is typically the power grid, a generator or a land connection. An inverter usually serves as an alternative source. With its switch -off time of less than 20 milliseconds, even sensitive loads continue to work without interruption.The Filax is not designed to supply household appliances with high electricity consumption, such as washing machines or electric motors.Gun switching functionThe Filax is a transfer switch with a gun (non -bridge) switching function. The maximum time for switching the loads is 16 ms. The load is usually supplied with the main generator and is switched to the alternative source in the following cases:
The voltage of the main power source falls below the threshold value.
The frequency of the main power source falls below the low frequency threshold value or it exceeds the high frequency threshold value.
Switching back from the alternative power source to the main source of the main power as soon as the voltage and frequency values of the main source of the main power are located for 30 seconds within the limit values specified for switching back.Technical specifications
Max. Electricity: 16A
Max. Time for switching: 16 ms
Switching delay for switching back: 30 seconds
Operating temperature range: -20 ° C - +50 ° C
Moisture (not condensing): max. 95%
Protection class: IP65
Weight: 0.8 kg
Dimensions: 120 x 255 x 75 mm
installation
Install the Filax in a dry and well -ventilated environment.
The input cables from the generator / main power supply and the output cables to the devices must be connected according to the circuit diagram.
When connecting a load with less than 850 watts, the wire bridges must be removed.
The frequency (50 Hz or 60 Hz) is set using a bridge. If the bridging is not set for the frequency, the switch-in threshold values for the voltage are incorrect.
Both inputs must be protected from electricity values of over 16 amps.
The front cover of the housing is attached using the four screws supplied.
The Filax is now ready for use.
Scope of delivery:
1x Victron Energy Filax Transfer switch SDFI00000004x fastening screws1x operating instructions
Small amount
EVC200300200
Victron Energy EV Charging Station II - Wallbox NS Blue
The EV Charging Station NS can be operated both three -phase and single -phase. It delivers a maximum of 22 kW alternating current in three -phase operation and 7.3 kW in single -phase operation. The device is technically identical to the EV Charging station, but has a new, modern design that is available in 3 colors and has no built-in LCD screen. The initial setup, configuration and monitoring takes place from VictronConnect via Bluetooth and/or the integrated web interface via a WiFi access point or a WiFi-LAN. The charging station can be fully integrated into a GX device and a VRM Victron Energy VRM and remotely controlled via it. This EV Charging Station NS is not only fully integrated with a GX device and a VRM VICTRON Energy, but can also be set so that excess solar energy can be used directly to load your vehicle. Manual and time -controlled modes offer even more flexibility to react to the needs of the electric vehicle depending on the system.
It has a fully programmable RGB glow ring around the loading connection, which depending on the power status (separated, loaded, loaded, loaded, etc.) shows different lighting effects in order to quickly determine the device status.https://youtu.be/uVVsdSj9pmg
Small amount
COS230502100
Victron VE Transfer switch 5KVA, single phase 200-250V AC
VE transmission switch
The VE Transfer Switch automatically switches between different power sources: between the generator and the country current, between inverter and the generator or between inverter and the country power.The VE Transfer Switch has two inputs and one output, it automatically transfers the available alternating current output to the output.
The VE Transfer Switch is available in two models:
5 KVA, one -phase, 200–250 VAC
10 KVA, one -phase, 200–250 VAC
Small amount
COS230103100
Victron VE Transfer switch 10kva, single phase 200-250V AC
VE transmission switch
The VE Transfer Switch automatically switches between different power sources: between the generator and the country current, between the inverter and the generator or between the inverter and the country power.The VE Transfer Switch has two inputs and one output, it automatically transfers the available alternating current output to the output.
The VE Transfer Switch is available in two models:
5 KVA, one -phase, 200–250 VAC
10 KVA, one -phase, 200–250 VAC
Small amount
THOR 07AS-S
Growatt APX 98034-P2 power module BMS
The newGrowatt APX 98034-P2 Battery management system is a control unit of the latest generation that protects each APX battery module from adverse conditions and ensures safe and disruptive continuous operation. It does not matter how many modules are in operation at the same time. It is important that one BMS per tower is always used. A tower consists of at least 1 to a maximum of 6 Growatt APX 5.0P-B1 5KWH high-voltage battery modules, which can result in a storage capacity of 5-30 kWh.
Monitoring parameterSocSystem voltageSystem currentCell tensionCell temperaturePCBA temperatureThe APX battery system:Thanks to the modular concept, the APX system can be used flexibly and can be expanded if necessary. A battery tower can be built with at least one to a maximum of 6 memory modules. A performance module is required for operation per tower. This is separate for purchase. An additional base is required for soil mounting.
Technical specifications:Dimensions: 690 x 185 x 295 mmWeight: 15kgMax. Electricity: 30ATop current: 34a, 60sCommunication: RS485/CanScope of delivery:1x Growatt APX 98034-P2 BMS
Small amount
RCD000300200
Victron Anti-Islanding Box 63a, for one and three-phase operation
The anti-Islanding box is a completely pre-cabled and easy-to-install device, which ensures that your battery system can be continued in the event of a network failure.If theoretically energy could be fed back into the public network from a battery system in the event of a network failure, an anti-Icelanding device must be installed in the battery system that corresponds to the local provisions. If there is a power failure in the electricity plant, this so -called ENS separates the connection to the network and its system continues as an independent system.
The anti-Islanding Box 63a one and three-phase, is a combination of an anti-Icelanding device, the UFR1001E anti-Icelanding relay, two inline shifting devices and one main performance switch. It is suitable for both single -phase and three -phase systems. It has a nominal output of up to 63 A per phase and all parts are conveniently housed in a housing of the protection class IP65.
The anti-Islanding box can be integrated into a network-sponsored inverter/charging system (ESS) in order to meet the local anti-Icelanding regulations.
The anti-Islanding Box 63a for single-phase and three-phase systems fulfills the following standards:
- G83/2 and G59/3 (proof of conformity Great Britain)
-VDE-AR-N 4105 (proof of conformity na protection Germany)
-ÖVE / ÖNORM E 8001-4-712 (Austria's obstruction)
-DIN V VDE V 0126-1-1 / A1 / NOI-RES_13E (objection certificate of Europe)
-NRS-097-2-1 (proof of conformity in South Africa)
The German, Austrian and French norms require two electrical switchgear switched in a row.
The Ziehl relay controls both switching devices.Note: The second shooter is not required for G83 / 2 and G59 / 3-compliant systems.
Not in stock
THOR 22AS-S
Growatt APX 98034-P2 power module BMS
The newGrowatt APX 98034-P2 Battery management system is a control unit of the latest generation that protects each APX battery module from adverse conditions and ensures safe and disruptive continuous operation. It does not matter how many modules are in operation at the same time. It is important that one BMS per tower is always used. A tower consists of at least 1 to a maximum of 6 Growatt APX 5.0P-B1 5KWH high-voltage battery modules, which can result in a storage capacity of 5-30 kWh.
Monitoring parameterSocSystem voltageSystem currentCell tensionCell temperaturePCBA temperatureThe APX battery system:Thanks to the modular concept, the APX system can be used flexibly and can be expanded if necessary. A battery tower can be built with at least one to a maximum of 6 memory modules. A performance module is required for operation per tower. This is separate for purchase. An additional base is required for soil mounting.
Technical specifications:Dimensions: 690 x 185 x 295 mmWeight: 15kgMax. Electricity: 30ATop current: 34a, 60sCommunication: RS485/CanScope of delivery:1x Growatt APX 98034-P2 BMS
Small amount
EVC200300310
Victron ev Charger ns black front panel
The EV Charging Station NS can be operated both three -phase and single -phase. It delivers a maximum of 22 kW alternating current in three -phase operation and 7.3 kW in single -phase operation. The device is technically identical to the EV Charging station, but has a new, modern design that is available in 3 colors and has no built-in LCD screen. The initial setup, configuration and monitoring takes place from VictronConnect via Bluetooth and/or the integrated web interface via a WiFi access point or a WiFi-LAN. The charging station can be fully integrated into a GX device and a VRM Victron Energy VRM and remotely controlled via it. This EV Charging Station NS is not only fully integrated with a GX device and a VRM VICTRON Energy, but can also be set so that excess solar energy can be used directly to load your vehicle. Manual and time -controlled modes offer even more flexibility to react to the needs of the electric vehicle depending on the system.
It has a fully programmable RGB glow ring around the loading connection, which depending on the power status (separated, loaded, loaded, loaded, etc.) shows different lighting effects in order to quickly determine the device status.https://youtu.be/uVVsdSj9pmg
Available (more than 10)
1111
Shelly Pro 3em 3-phase current consumption meter incl. 3x current transformers 120a
The electricity meter Victron EM540 (MPN Rel200100100) is designed to monitor three-phase operating modes, for example PV inverter, ACoric unit or inverter. In this way you can measure the performance and energy of the entire system as a direct measurement in the distribution box. The Victron EM540 uses a higher sampling speed compared to the EM24. It is suitable as a supplement to an inverter/charger from Victron.
The device offers two options for connecting to a GX device:
Cable connection via RS485-to-USB interface with a cable length of 1.8m or 5mWireless connection via Zigbee-to-USB and Zigbee-to-RS485 converterThe article at a glance
Usable as a network meter and as a tax input for an eating systemCan be used to measure the performance of a PV inverter or an ACoric unitSupport of different types of energy countersChoice between RS485 and intact Ethernet connection possibleUse for displaying the data on a GX deviceTechnical specifications:
Manufacturer number number: Rel200100100Display: LCDPhases: suitable for 3 phasesMax. Nominal current: 65a per phaseMass type: Direct/ShuntCommunication: RS485Scope of delivery:
1x Victron Energy EM540 Energy Meter 3-Phasig (Rel200100100
)
Small amount
EVC200300410
Victron ev Charger ns white front panel
The EV Charging Station NS can be operated both three -phase and single -phase. It delivers a maximum of 22 kW alternating current in three -phase operation and 7.3 kW in single -phase operation. The device is technically identical to the EV Charging station, but has a new, modern design that is available in 3 colors and has no built-in LCD screen. The initial setup, configuration and monitoring takes place from VictronConnect via Bluetooth and/or the integrated web interface via a WiFi access point or a WiFi-LAN. The charging station can be fully integrated into a GX device and a VRM Victron Energy VRM and remotely controlled via it. This EV Charging Station NS is not only fully integrated with a GX device and a VRM VICTRON Energy, but can also be set so that excess solar energy can be used directly to load your vehicle. Manual and time -controlled modes offer even more flexibility to react to the needs of the electric vehicle depending on the system.
It has a fully programmable RGB glow ring around the loading connection, which depending on the power status (separated, loaded, loaded, loaded, etc.) shows different lighting effects in order to quickly determine the device status.https://youtu.be/uVVsdSj9pmg