Shore Power
- News
- Complete Systems
- Batteries
- Electronics
- Installation
- Expansion
- Solar Technology
- Marken
Filter
–
Small amount
SHP301602000
Victron stainless steel built-in socket boat camper yacht shore connection 16A
The Victron shore power socket SHP301602000R 16A was specially developed for the boat and mobile home sector. This model features a high quality stainless steel bezel and is compatible with all Victron shore power cables.
Technical characteristics:
Degree of protection: IP 57
Facing Material: Stainless steel
Weight: 0.34kg
max voltage: 250V AC
max current: 16A
Standard: IEC 60309, 2p+E
Type coverage: PA6
Scope of delivery:
1x Victron SHP301602000R shore power socket 16A 250V stainless steel
Delivery time: 1-3 working days
Small amount
SHP303202000
Victron stainless steel built-in socket shore connection boat mobile home yacht 32A
The Victron shore power socket SHP303202000 32A was specially developed for the boat and mobile home sector. This model has a high quality stainless steel cover and is compatible with all Victron shore power cables.
technical characteristics
Degree of protection: IP 57
Facing Material: Stainless Steel
Weight: 0.65
Max current: 32A
Standard: IEC 60309, 2p+E
Type cover: PA6
Scope of delivery:
1x Victron SHP303202000 shore power socket 32A stainless steel
Delivery time: 1-3 working days
data sheet
General
item number
8-67-009225
Manufacturer part number
SHP303202000
product type
high-quality 32A stainless steel junction box for shore power cables in the marine and caravan sector
Manufacturer
VictronEnergy
EAN
8719076026099
Available (more than 10)
SHP307700280
Victron adapter CEE plug 16A 3p to CEE coupling 32A 3p 250V
Victron adapter CEE plug 16A 250V 3-pin to CEE coupling 32A 250V 3-pin
max. Current: 32A
Max. voltage: 250V AC
In the shore connection area you will find additional adapters, shore power cables and built-in sockets made of stainless steel and polyamide.
Scope of delivery:
1x Victron Energy SHP307700260 Adapter CEE plug 16A 250V 3-pin to CEE coupling 32A 250V 3-pin
Small amount
6227498270893
Siemens 5SU1356-6KK10 RCCB 2-pole 10A 0.03A 230V
Technical details
Frequency
50Hz
Connectable conductor cross section stranded
0.75 | 35.0
Number of poles (total)
2
Energy Limit Class
3
Rated breaking capacity according to EN 61009
6.0
Rated breaking capacity according to IEC 60947-2
15.0
Rated switching capacity Icn according to EN 61009-1
6.0
Type of stress
AC
Width in pitch units
2
False trip protection
yes
Number of fused poles
1
Rated residual current
0.03
Suitable for flush-mount installation
yes
degree of protection (IP)
IP20
Rated voltage
230
Rated insulation voltage Ui
264
Rated impulse withstand voltage Uimp
4.0
Rated current
10
surge current resistance
1.0
Release characteristic
B
Switching neutral conductor
yes
With locking device
yes
Overvoltage Category
3
degree of pollution
2
Ambient temperature during operation
-25 | 55
Installation depth
70.0
Connectable conductor cross-section, solid
0.75 | 35.0
Delivery time: 1-3 working days
Small amount
73540301
Spelsberg AK 03 small distributor, 3 modular widths, 1 row, IP65
Safe - Thanks to the high degree of protection IP65 and the robust, halogen-free design, safe operation is guaranteed even under harsh industrial environmental conditions.
Material:
Box: polystyrene, light gray similar to RAL 7035
Lid: polystyrene, light gray similar to RAL 7035
Hinged window: polycarbonate, transparent
Seal: Polyurethane
Cover screw: Polyamide 6, glass fiber reinforced
More properties:
Color: grey
Protection class: IP65 - according to EN 60529 / DIN VDE 0470-1
Number of pitch units: 3
Heavy metal free
PVC-free
Silicone-free
sealable
Impact strength: IK07 according to DIN EN 5012 / VDE 0470 part 100
Cover screw torque: 1.2 N m
Environmental conditions:
Ambient temp. (minimum): -25°C
Ambient temp. (maximum): 40°C
Ambient temp. (24 hours): 35°C
Max. rel. Humidity at 25°C (short term): 95%
Max. rel. Humidity at 40°C: 50%
Dimensions:
Width: 100mm
Length: 150mm
Height: 96mm
Internal height: 95mm
?Delivery time: immediately from stock
Small amount
010002110
PHILIPPI shore connection unit LAE 211
Shore connection unit for mains power takeover 230V/50Hz with Schuko socket. Mains control lamp shows mains status. Internal mains connection directly to the terminals of the RCBO circuit breaker, cable entry with PG screw connection. Splash-proof all-plastic housing with hinged lid. Degree of protection IPX4.
Power indicator light
RCBO circuit breaker 16A/0.03A 2-pole
Dimensions: W 97 x H 246 x D 97mm
Not in stock
SHP301603000
Victron 16A polyamide installation socket boot motorhome yacht
The Victron country power socket SHP301603000R 16A was specially developed for the boat and motorhome area. This model has a high-resistant polyamide fading and is compatible with the Victron country power cables.
Technical characteristics
Protection class: IP 57
Dealing material: polyamide
Weight: 0.34kg
Max. Tension: 250V AC
Max. Electricity: 16A
STANDARD: IEC 60309, 2P+E
Typing cover: pa6
Â
Scope of delivery:
1x Victron SHP301603000R Landstrom socket 16A 250V polyamide
Small amount
SHP302502500
Victron shore power cable 25m 16A H07BQ-F 3x2.5mm=
The Victron Energy 25m shore power cable for the marine sector. (MPN SHP302502500) consists of 25m armored cable H07BQ-F 3G2.5mm. This cable is therefore suitable for the most extreme operating conditions and is virtually indestructible. Victron uses extra strong cables (2.5mm²) so that the safety devices on your shore connection also work reliably.
Heavy-duty outer jacket
Polyurethane outer jacket, mechanically highly resilient, extremely tear-, cut- and abrasion-resistant, highly flexible, oil-resistant, extremely weather-resistant, for continuous outdoor use. Temperature range -40 degrees to +90 degrees.
Technical features at a glance
Length: 25m
Max Voltage: 250V AC
Max current: 16A
Cable type: H07BQ-F
Wire cross-section: 2.5mm²
Number of cores: 3
Land plug type: IEC60309 molded 2-pin + earth
Board connector type: IEC60309 3-pin
Deployment Area: Marine Area
Weight: 4.3 kilograms
Scope of delivery:
1x Victron Energy SHP302502500 25m shore power cable 3x2.5mm² H07BQ-F
Delivery time: 1-3 working days
Small amount
SHP307700300
Victron adapter 32A CEE coupling 3p to 32A CEE plug 5p
Victron adapter 32A CEE coupling 3-pin to 32A CEE plug 5-pin.
Max current: 32A
Max Voltage: 250V AC
In the shore connection area you will find additional adapters, shore power cables and built-in sockets made of stainless steel and polyamide.
Scope of delivery:
Victron Energy SHP307700300 Adapter 32A CEE coupling 3-pin to 32A CEE plug 5-pin
Small amount
010000231
Philippi LAR on-board network control for the AC network
The network control panel LAR shows the electrically correct connection of the AC-BRONZ network to the AC land network: Green light: Everything connected correctly, red light: phase (L) and zero conductor (s) are exchanged. Measuring error current 1.4 mA, not suitable for AC networks without protective conductor, since no error detection is possible here.The consumer supplies are connected via flat stains 6.3mm on the back.The panel is to be installed in such a way that the back is only accessible and covered with tools.The installation section can be selected by 12 mm per edge smaller than the panel dimensions (81 x 28.5 mm).Dimensions: W 105 x H 52.5 x D 50 mm
Available (more than 10)
SHP307700240
Victron splitter 16A 250V CEE plug to 2x CEE coupling
Victron splitter CEE plug to 2x CEE coupling.
max. Current: 16A
Max. voltage: 250V AC
In the Victron shore power cable series for the marine sector you will find additional adapters, shore power cables and built-in sockets made of stainless steel and polyamide.
Scope of delivery:
1x Victron Energy SHP307700240 splitter 16A/250V CEE plug to 2x CEE coupling
Not in stock
SHP302501500
Victron shore power cable 15m 16A H07BQ-F 3x2.5mm=
The Victron Energy 15m shore power cable for the marine sector. (MPN SHP302501500) consists of 15m armored cable H07BQ-F 3G2.5. This cable is therefore suitable for the most extreme operating conditions and is virtually indestructible. Victron uses extra strong cables (2.5mm²) so that the safety devices on your shore connection also work reliably.
Heavy-duty outer jacket
Polyurethane outer jacket, mechanically highly resilient, extremely tear, cut and abrasion resistant, highly flexible, oil-resistant, extremely weather-resistant, for continuous outdoor use. Temperature range -40 degrees to +90 degrees.
Technical features at a glance
Length: 15m
max. Voltage: 250V AC
max. Current: 16A
Cable type: H07BQ-F
Core cross-section: 2.5mm²
Number of cores: 3
land plug type: IEC60309 potted 2-pin + earth
board connector type: IEC60309 3-pin
Area of ​​application: Marine
Weight: 2.66 kilograms
Scope of delivery:
1x Victron Energy SHP302501500 15m shore power cable 3x2.5mm² H07BQ-F
Small amount
010001010
Philippi shore connection unit LAE101
Type philippi LAE 101
Shore connection unit for 230 V/50 Hz mains power supply with Schuko socket for the 230 V on-board supply. The power indicator light shows the correct power connection. The connection is made on the back using feed-through terminals.
Technical data:
FI/LS circuit breaker RCBO 16A/0.03A 2-pole
Dimensions W 185 x H 150 x D 100 mm
cut-out dimensions W 160 x H 125 mm
Small amount
010002300
Philippi shore connection unit LAE230
Type Philippi LAE 230
Shore connection unit for mains power takeover 230 V/50 Hz with 2-pin. RCBO circuit breaker and 2 circuit breakers.
Mains control lamp shows mains status.
Internal connections, directly on the terminals of the circuit breakers.
Cable entry with self-sealing grommet.
Waterproof plastic housing with hinged cover, protection class IP 65.
Dimensions W 160 x H 200 x D 115 mm
Small amount
SHP306002500
Victron shore power cable 25m 32A H07BQ-F 3x6mm=
The Victron Energy 25m shore power cable for the marine sector. (MPN SHP306002500) consists of 25m armored cable H07BQ-F 3G6.5. This cable is therefore suitable for the most extreme operating conditions and is virtually indestructible. Victron uses extra strong cables (6.5mm²) so that the safety devices on your shore connection also work reliably.
Heavy-duty outer jacket
Polyurethane outer jacket, mechanically highly resilient, extremely tear, cut and abrasion resistant, highly flexible, oil resistant, extremely weather resistant, for continuous outdoor use. Temperature range -40 degrees to +90 degrees.
Technical features at a glance
Length: 25m Max Voltage: 250V AC Max current: 32A Cable type: H07BQ-F Wire cross-section: 6.5mm² Number of cores: 3 Land plug type: IEC60309 molded 2-pin + earth Board connector type: IEC60309 3 pin Area of ​​application: Marine area Weight: 18 kilograms
Scope of delivery: 1x Victron Energy SHP306002500 25m shore power cable 3x6.5mm² H07BQ-F
Small amount
ITR000100101
Victron car transformer 120/240VAC-100A
The Spartransformer: For the compensation of upward, tensioning and splitting phasesA savings transformer can be used to compensate for upward, tensioning and gap phase outputs. While the upward and crooking functions are quite simple, the compensation of the split phase output requires a little more attention.As an example, we take a split phase supply of 30 A 120/240 V.The supply can take place via the network, a generator or two linked inverters.Some of the connected loads require 240 V, other 120 V. The load 30 A should not exceed on each 120 V cycle. It is problematic that the two cycles have different electricity as soon as 120 V loads are connected. The reason for this is that the 120 V loads on the two cycles will never be balanced. A 120 V hair dryer with 1200 W, for example, pulls 10 A of a circulation. A 120 V washing machine can even pull more than 20 A of a circulation. The electricity difference between the two cycles, also called electricity unmetry, is therefore often 20 A or more. This means that the 30 A supply is not fully exploited. As soon as a cycle 30 A pulls, the other cycle may not pull more than 10 A. An increase in the 240 V load, for example, then leads to an overload of the one circulation, while the other circulation still has free capacity.In theory, the total power of a power supply with 30 A and 120/240 V = 30 x 240 = 7.2 kVA is.In the case of an unimmetry of 20 A, the practical maximum is 30 x 120 + 10 x120 = 4.8 kva or 67 % of the theoretical maximum.The solution is a savings transformer.If you leave the neutral manager of the split phase supply unused and connect a savings transformer as a new zero -conductor, as shown in Figure 1, every unimmetry of the load is "absorbed" by the Spartransformer.In the event of a 30 A supply, the load can be increased to 7.2 KVA. A 20 A-UNSYMMETRE The load leads to the fact that one circulation 40 a and the other 20 A delivers. The difference of 20 A flows through the zero conductor and the coil of the Spartransformer. The electricity due to the two 120 V lines of the split phase supply is 30 A.Including ground relay for use with Multi or Quattro interverters/chargersWhen operating in the inverter mode, the zero manager of the inverter/charger must be connected to the ground to ensure the proper functioning of a GFCI. In the event of a split phase supply, the zero conductor must be grounded. For this purpose, an ground relay is installed in the housing of the Spartransformer. The relay is controlled by the 230/240V Multi or Quattro. (The internal ground relay of the 230/240 V Multi or Quattro must be deactivated)Temperature -protectedIn the event of overheating, the savings transformer is separated from the power supply. The reset is manually.An alternative to coupled invertersThe alternative to the coupling of two 120 V interverters for a 120/240 V-split phase supply is a 240 V-inverter with an additional saving transformer.Two stacked 120 V inverters with 3 KVA deliver up to 25 A to every 120 V cycle. If the load is less than 25 A on a cycle, the maximum load on the other cycle is still limited to 25 A.A 240 V inverter with 5 KVA and a 32 A-saving transformer supplies each 120 V circuit with a balanced load of up to 21 A. However, fewer loads on a circulation lead to the fact that more power is available on the other cycle, however The maximum wirmmetry is 32 A.The load can therefore be up to 38.5 A on a circulation if the load on the other cycle is no more than 3.5 A (maximum wiring: 38.5 / 3.5 / 35 a if with an asymmetrical load too is therefore a 240 V inverter with a lower power and saving transformer of the solution with coupled inverters.
Small amount
111400016
Siemens 5SU1356-6KK10 FI Circuit Breaker 2-pole 10A 0.03A 230V
Einpoliger thermischer Überstromschutzschalter in Kleinbauweise. Zuverlässiges Schaltverhalten durch Sprungschaltmechanismus und unbeeinflussbare Freiauslösung. Entspricht den neuen Geräteschutzschalter-Richtlinien EN 60934. Lochauschnitt 22 x 11,3 mm. DC 48 V, AC 240 V. Nennstrombereich 2...16 A