Battery voltage range:
9 - 60VDC
Maximum input voltage:
75VDC
Supported system voltages:
12, 24 or 48V
Protection against reverse polarity:
No
Continuous current of the main safety circuit:
1000A continuous
Nominal current of the main safety circuit:
1200A for 5 minutes
Power consumption OFF mode:
0.3mA for all system voltages
Power consumption in standby mode:
approx. 0.6W (50mA at 12V)
Power consumption in ON mode:
approx. 4.2W (350mA at 12V), depending on the status of the relays
Minimum load resistance for precharging:
10Ω and more for 12V systems, 20Ω and more for 24V and 48V systems
AUX output maximum rated current:
1.1A continuous current, protected by a resettable fuse
Permitted connection for charging, max. rated current:
0.5A at 60VDC, protected by a resettable fuse
Permissible connection for discharging, max. rated current:
0.5A at 60VDC, protected by a resettable fuse
Alarm relay (SPDT) max. rated current:
2A at 60VDC