Mains voltage (mains frequency 45 - 65 Hz) |
110V-230V |
| |
Mains working voltage range, all types |
85V - 270V, momentary 305V (5 sec) |
| |
Mains voltage range for full charging power |
95V - 270V |
| |
Mains power consumption max. |
240W |
| |
Current consumption (AC) max. |
2.7A |
| |
Device switch stand-by |
1.2W |
| |
Active sinusoidal power factor correction (CosPhi <= 1) |
yes |
| |
charging current approx. at 110V mains voltage |
15A |
| |
Charging outputs battery I + II |
| |
Battery nominal voltage lead/LiFePO4 battery |
12V / 12V-13.3V |
| |
Battery capacity I or I+II (recommended) |
60Ah - 110Ah |
| |
Battery capacity I or I+II (depending on application) |
38Ah - 170Ah |
| |
Charging current main charge total, I-phase, 8 V to U1; 0-15.5h |
15A |
| |
Charge/buffer/load current, regulated U1-U2-U3 phase |
0A - 15A |
| |
Automatic charging current distributor for batt. I / battery II |
yes |
| |
Minimum battery voltage for charging start |
0V |
| |
Pre-charging current, deeply discharged batteries 0 V - 8 V |
7.5A |
| |
Back current from battery (mains failure) |
<0.5mA |
| |
Reset voltage (30 sec), battery type dependent |
12.75V / 13.25V |
| |
Charging voltage limit (protection of connected consumers) |
15.0V |
| |
External overvoltage shutdown (20 sec) |
15.5V |
| |
Voltage Ripple |
<30mVrms |
| |
Load timer |
quadruple |
| |
reverse polarity/short circuit/back discharge/safety protection |
yes |
| |
Safety timer for each charging phase I-/U1-/U2 |
yes |
| |
Lead battery regeneration in case of long standstill, 2x weekly. 1h |
yes |
| |
LiFePO4 auto-wake up for long periods of standstill, 10 days 0.5 h |
yes |
| |
or LiFePO4 lithium sleep float (seasonal use) |
yes |
| |
Manual lead-acid equalization charge, equalization, charging current |
2.5A |
| |
Equalization, charging voltage/charging time limit max. |
16.0V/1.5h |
| |
Main charging output battery I (master) |
| |
Selectable charge programs lead gel/AGM/acid, LiFePO4 |
8 |
| |
Charge/buffer/load current, regulated IU1oU2oU3 phase |
0A - 15A |
| |
Input for battery temperature sensor |
yes |
| |
Power supply operation (e.g. continued supply when changing the battery) |
yes |
| |
2. Charging output battery II (built-in charging current distributor, switchable) |
| |
8 charging programs optionally the same as battery I |
yes |
| |
or charging program for vehicle (lead) starter battery |
yes |
| |
Charge/buffer/load current, regulated IU1oU2oU3 phase |
0A - 15A |
| |
3. Next to charging output III (mains signaling output) |
| |
Battery nominal voltage (lead) |
12V |
| |
Charging current or load capacity as signaling output |
0A - 2A |
| |
reverse polarity/short circuit/back discharge/safety protection |
yes |
| |
Connection for remote control Automatic Charger |
yes |
| |
Device installation position |
any |
| |
Temperature range |
-20/+45 °C |
| |
Speed-controlled, temperature-controlled fan |
yes |
| |
Gradual curtailment of the charging power in the event of overtemperature |
yes |
| |
Overheating safety shutdown |
yes |
| |
Fan noise reduction, night mode (Silent Run) |
yes |
| |
Protection class/degree of protection |
I / IP21 |
| |
Dimensions - Dimensions including mounting flanges, without connections
|
205x160x72mm |
| |
weight |
1250g |
| |
Ambient conditions, humidity |
max. 95% RH non-condensing |
| |
Safety regulations |
EN 60335-2-29 |
| |
Scope of delivery power cable, 1 temperature sensor, operating instructions |