Network voltage (network frequency 45 - 65 Hz) |
110 V - 230 V |
Network function voltage area, all types |
85 V - 270 V, briefly 305 V (5 seconds) |
Network voltage area for full charging power |
180 V - 270 V |
Network performance max. |
490 W |
Network performance recording at loading management |
1.9 W |
Active sinus-shaped power factor correction (Cosphi <= 1) |
Yes |
Charging current approx. 110 V network voltage |
18 A |
Main charging output battery I |
Battery native voltage lead/lifepo4 battery |
12 V / 12 V-13.3 V |
Selectable charging programs lead gel/AGM/acidity, lifepo4 |
4 |
Battery capacity (recommended) |
120 Ah - 230 Ah |
Battery capacity (after application, e.g. Lifepo4) |
75 Ah - 350 Ah |
Charging current main load, i-phase, 8 V to U1; 0-15.5 h |
30 a |
Loading/buffer/load current, regulated U1-U2-U3 phase |
0 a - 30 a |
Minimum battery voltage for the start of the load |
0 V |
Preliminary flow, lowest -download batteries 0 V - 8 V |
15.0 a |
Return current made of battery (power failure) |
<0.5 MA |
Reset voltage (30 sec), battery type dependent |
12.75 V / 13.25 V |
Charging stress limit (protection of affiliated consumers) |
15.0 V |
External overvoltage shutdown (20 sec) |
15.5 V |
Tension |
<30 MV RMS |
Charging timer |
4-fold |
Group/short circuit/back load/safety protection |
Yes |
Safety timer per loading phase I-/U1-/U2- |
Yes |
Lead battery regeneration with a long service life, 2x aw. 1 H |
Yes |
Lifepo4 car Wake Up at a long time, 10 daily 0.5 h daily |
Yes |
or Lifepo4 lithium rest conservation (seasonal company) |
Yes |
Input for battery temperature sensor |
Yes |
Power supply operation (e.g. further supply for battery changes) |
Yes |
2. Sideline Vehicle Starter Battery II (registration output network) |
Battery native voltage (lead) |
12 V |
Charging current or resilience as a registration output |
0 a - 2 a |
Group/short circuit/back load/safety protection |
Yes |
Connection for remote control automatic charger |
Yes |
Device installation position |
any |
Temperature range |
-20 / +45 ° C |
Speed -controlled, temperature -controlled fan |
Yes |
Gradual delegation of the charging capacity at over temperature |
Yes |
Safety shutdown at overheating |
Yes |
Fan noise lowering, night operation (Silent Run) |
Yes |
Protection class / protection class |
I / IP21 |
Dimensions, Dimensions including fastening flanges/feet, without connections
|
228 x 139 x 74 mm |
Weight |
1350 g |
Ambient conditions, humidity |
Max. 95 % RF, not condensing |
Safety regulations |
EN 60335-2-29 |
Scope of delivery: network cable, operating instructions |