| Network voltage (network frequency 45 - 65 Hz) |
110 V - 230 V |
| Network function voltage area, all types |
85 V - 270 V, briefly 305 V (5 seconds) |
| Network voltage area for full charging power |
190 V - 270 V |
| Network performance max. |
680 W |
| Network current recording (AC) Max.: |
5.2 a |
| Active sinus-shaped power factor correction (Cosphi <= 1) |
Yes |
| Charging current approx. 110 V network voltage |
32 a |
| Switch "AC Power Limit", limitation of the network electricity recording / performance: |
| Position "max" (maximum charging power): |
5.2 A / 680 W |
| Position "med" (reduced network and charging power): |
1.9 A / 390 W |
| Position "low" (reduced network and charging power): |
1.4 A / 280 W |
| Load outputs Batteries "A" + "B": |
| Battery native voltage lead/lifepo4 battery |
12 V / 12 V-13.3 V |
| Battery capacity adjustable (A or A+B total) |
75 AH-480 Ah |
| Charging current i-phase (A, B or A+B) Max |
40 A |
| Loading/buffer/load current, regulated U1-, U2-, U3 phase |
0 a - 40 a |
| Automatic charging current distributor Batteries A / B: |
Yes |
| Minimum battery voltage for the start of the load |
0 V |
| Preliminary flow, lowest -download batteries 0 V - 8 V |
20 A |
| Return current made of battery (power failure) |
<0.2 ma |
| Reset voltage (30 sec), battery type dependent |
12.75 V / 13.25 V |
| Charging stress limit (protection of affiliated consumers) |
15.0 V |
| External overvoltage shutdown (20 sec) |
15.5 V |
| Tension |
<40 MV RMS |
| Charging timer |
4-fold |
| Group/short circuit/back load/safety protection |
Yes |
| Safety timer per loading phase I-/U1-/U2- |
Yes |
| Feeler lines "Sense" input, for "-" battery and "+A", "+B" |
Yes |
| Lead battery regeneration with a long service life, 2x aw. 1 H |
Yes |
| Lifepo4 car Wake Up at a long time, 10 daily 0.5 h daily |
Yes |
| or Lifepo4 lithium rest conservation (seasonal company) |
Yes |
| Main charging output battery "A" (master): |
| Selectable charging programs lead gel/AGM/acidity, lifepo4 |
4 |
| Loading/buffer/load current, regulated iu1ou2ou3 phase |
0 a - 40 a |
| Input for battery temperature sensor |
Yes |
| Power supply operation (e.g. further supply for battery changes) |
Yes |
| 2nd charging output battery "B" (built -in charging current distributor, switchable): |
| Charging programs optionally like battery "A" Master |
Yes |
| or charging program for vehicle (lead) starter battery |
Yes |
| Loading/buffer/load current, regulated iu1ou2ou3 phase |
0 a - 40 a |
| Input for battery temperature sensor "B" |
Yes |
| Power supply operation (e.g. further supply for battery changes) |
Yes |
| 3. In addition to charging output "C" (registration output network): |
| Battery native voltage (lead) |
12 V |
| Charging current or resilience as a registration output |
0 a - 2 a |
| Overload/ discharge/ short circuit/ back load/ safety protection |
Yes |
| Connection for remote control automatic charger |
Yes |
| Device installation position |
any |
| Temperature range |
-20/+45 ° C |
| Speed -controlled, temperature -controlled fan |
Yes |
| Gradual delegation of the charging capacity at over temperature |
Yes |
| Safety shutdown at overheating |
Yes |
| Fan noise, night operation (Silent Run) |
Yes |
| Protection class / protection class: |
I / IP21 |
| Dimensions, including fastening flanges/feet |
330 x 139 x 74 mm |
| Weight: |
2400 g |
| Ambient conditions, humidity |
Max. 95 % RF, not condensing |
| Safety regulations |
EN 60335-2-29 |
| Scope of delivery: network cable, operating instructions |