| Entrance of the vehicle starter battery "+ in Start" |
| Vehicle starter battery nominal voltage |
24 V |
| Battery capacity (size), at least recommended |
60 Ah |
| Input voltage area (Euro 6 +), D + controlled |
22 - 32 V |
| Input overvoltage shutdown (Euro 6 +), max. |
32.2 V |
| Performance recording max. |
740 W |
| Electricity intake (with the lowest input voltage) max. |
30 a |
| Electricity intake standby / off (KL.15 or D+ without signal) |
0.11 a / 5 ma |
| Charging output on on-board supply battery "+ Out Bord" |
| Battery |
12.8 V - 13.2 V |
| Battery capacity recommended / up to |
90-300/400 Ah |
| Charging current Hauptladg., I-phase, 8 V to U1, 0-15h |
45 a |
| Loading/buffer/load current, regulated U1-U2 phase |
0 - 45 a |
| Selectable charging programs Lifepo4 |
4 |
| Minimum battery voltage for the start of the load |
0 V |
| Vorbadestrom (Battery deepest discharge <8V), max. |
22.5 a |
| Return current made of battery, off (KL.15 or D+ without signal) |
0 A |
| Reset voltage Lifepo4 (30sec) |
12.75 V |
| Charging limit limit (protection of consumers) |
15.00 V |
| External overvoltage shutdown (20sec) |
15.20 V |
| Tension |
<30 MV RMS |
| Input for battery I-Temperature sensor |
Yes |
| Charging timer |
3-way |
| Group/short circuit/back load/safety protection |
Yes |
| Overload protection |
Yes |
| Security timer per load phase I / U1 |
Yes |
| EBL Start in, EVS measurement input / charging output |
<30 MV RMS |
| Load/cargo maintenance for 12 V-starter battery |
0 ... 3 a |
| Device installation position |
any |
| Temperature range |
-20 to 45 ° |
| Speed -controlled, temperature -controlled fan |
Yes |
| Gradual delegation of the charging capacity at over temperature |
Yes |
| Safety shutdown at overheating |
Yes |
| Dimensions, including fortified. Flanges and clamps (LXBXH) |
245 x 160 x 71 mm |
| Weight |
1700 g |
| Ambient conditions, humidity: max. 95 % room moisture, not condensing |
| Scope of delivery: temperature sensor, operating instructions |