Versand in 1-3 Werktagen
- Charging programs no. 1, 2, 4 and Li (gel, AGM, acid, LiFePO4) adjustable to battery type
- The charging voltage is peak-free and regulated in such a way that the batteries cannot be overcharged.
- Fully automatic continuous operation: The charger can be constantly connected to the battery and keeps it fully charged. In the event of a power failure, the batteries are not discharged (separation by safety switch).
- Lithium LiFePO4- Maintenance, Auto Wake Up, maintenance phase: Regular automatic activation of the battery cell balancing every 10 days to ensure that the battery is fully charged.
- Twice a week lead-acid battery regeneration during long standstill periods to prevent harmful acid stratification.
- Parallel and buffer operation: If the battery is consumed at the same time, it continues to be charged or is kept full. The charging times are automatically calculated and monitored by the charger.
- Charging without monitoring: Multiple protection against overload, overheating, overvoltage, short circuit, polarity reversal, incorrect behavior and reverse battery discharge through electronic regulation up to complete separation of charger and battery through built-in safety switch.
- Connection for battery temperature sensor (temperature sensor 825 accessory, item no. 2001): With lead batteries (acid, gel, AGM), the charging voltage is automatically adjusted to the battery temperature In the cold, the weaker battery is better fully charged, and unnecessary battery gassing and thus battery stress are avoided in summer temperatures.
With LiFePO4 batteries, the battery temperature sensor is required for the function: It protects the battery at high and especially at low temperatures below 0°C. - Silent run function: noise-optimized operation at the touch of a button (night mode).
- Power pack function: Allows the consumers to be supplied without a battery (e.g. changing the battery).
- Charging cable compensation: Voltage losses on the charging cables are automatically compensated.
- Built-in on-board network filter: Problem-free parallel operation with solar systems, wind and petrol generators, alternators, etc. on one battery.
- Charging aid for deeply discharged lead batteries: Gentle pre-charging of the (lead-acid, -gel, -AGM) battery up to 8 V, then powerful support for the battery if consumers are still switched on.
- Battery disconnection in the event of a power failure, overheating, malfunction (safety switch per charging output)
- Separate secondary charging output "S" for support and trickle charging of the vehicle starter battery
Also available in boat version with moisture-proof electronics!
Technical data
Mains voltage (mains frequency 45 - 65 Hz) | 110V-230V |
Mains working voltage range, all types | 85V - 270V, momentary 305V (5 sec) |
Mains voltage range for full charging power | 180V-270V |
Mains power consumption max. | 400W |
Mains power consumption when ready to charge | 1.9W |
Active sinusoidal power factor correction (CosPhi <= 1) | yes |
charging current approx.at 110 V mains voltage | 18A |
Main charging output battery I | |
Battery nominal voltage lead/LiFePO4 battery | 12V/12V-13.3V |
Selectable charge programs lead gel/AGM/acid, LiFePO4 | 4 |
Battery capacity (recommended) | 100Ah - 180Ah |
Battery capacity (depending on the application, e.g. also LiFePO4) | 60Ah - 290Ah |
Charge current, main charge, I phase, 8 V to U1; 0-15.5h | 25A |
Charge/buffer/load current regulated U1-U2-U3 phase | 0A - 25A |
Minimum battery voltage for charge start | 0V |
Pre-charging current, deeply discharged batteries 0 V - 8 V | 12.5A |
Reverse current from battery (mains failure) | <0.5mA |
Reset voltage (30 sec), battery type dependent | 12.75V / 13.25V |
Charge voltage limit (protection of connected consumers) | 15.0V |
External Over Voltage Shutdown (20 sec) | 15.5V |
Voltage Ripple | <30mVrms |
Load timer | quadruple |
Reverse polarity/short circuit/back discharge/safety protection | yes |
Safety timer per charging phase I-/U1-/U2- | yes |
Lead-acid battery regeneration in the event of a long standstill, 2x a week. 1h | yes |
LiFePO4-Auto Wake Up for long periods of standstill, 10 daily 0.5 h | yes |
or LiFePO4 lithium dormant float (seasonal) | yes |
Input for battery temperature sensor | yes |
Mains power supply operation (e.g. continued supply when changing batteries) | yes |
2. Auxiliary output for vehicle starter battery II (mains signaling output) | |
Battery Nominal Voltage (Lead) | 12V |
Charging current or load capacity as signaling output | 0A - 2A |
Reverse polarity/short circuit/back discharge/safety protection | yes |
Connection for remote control Automatic Charger | yes |
Device installation position | any |
temperature range | -20 / +45 °C |
Speed-controlled, temperature-controlled fan | yes |
Gradual curtailment of charging power at overtemperature | yes |
Overheat Safety Shutdown | yes |
Fan noise reduction, night mode (Silent Run) | yes |
protection class / degree of protection | I / IP21 |
Dimensions, Dimensions including mounting flanges/feet, without connections | 228x139x74mm |
Weight | 1300g |
Ambient conditions, humidity | max. 95% RH non-condensing |
Safety regulations | EN 60335-2-29 |
Scope of delivery: power cord, user manual |