ÖLFLEX® SOLAR XLR-R cables are weather, abrasion and UV-resistant photovoltaic cables. These halogen-free, double-insulated and cross-linked solar cables are suitable for permanent outdoor use to connect grounded and ungrounded photovoltaic systems. They are used both for wiring solar modules to one another and for connecting the individual rows of modules and the inverter. The cable has been tested by TÜV Rheinland according to 2 PfG 1169/08.2007 (PV1-F) type.
Important product features:
Cable cross section: 6mm
Manufacturer: Lapp Kabel
Outer insulation color: black
Insulation color: white
XLR-R solar cables from Lapp can basically be laid in protective pipes suitable for burial in the ground if it is ensured that there is no permanent contact with water and waterlogging is safely drained away. The laying of the cables in the ground and the correct design of the cable trench must comply with VDE 0100 Part 520 or comparable standards in order to prevent damage to the protective tube and permanent exposure of the cables and lines to penetrating water. Long-term, permanent storage and permanent operation of the lines in or under water is not permitted.
Construction of conductors
1. Conductor: Fine-wire strand made of tinned copper wires, according to IEC 60228, class 5
2. Wire insulation: electron beam cross-linked polyolefin co-polymer
3. Outer jacket Electron beam crosslinked polyolefin co-polymer outer jacket color: black or black with red or blue stripes
Electrical properties
Rated voltage: U0 /U according to IEC AC 600/1000 V DC 900/1500 V
Max. Permissible system voltage: 1.8 kV DC (conductor/conductor, non-earthed system) according to TÜV 2 PfG 1169/08.2007 Test voltage AC 6.5 kV
Thermal properties
Temperature range fixed: -40° C to +120° C max. conductor temperature (according to EN 60216- 2)
Temperature range according to: -40 °C to +90 °C ambient temperature TÜV 2 PfG 1169/08.2007
Flexible laying temperature: max. -25 °C
Heat pressure resistance according to EN 60811-3-1
Damp-heat test according to EN 60068-2-78 at 85% humidity
Mechanical properties
Minimum bending radius occasionally moved: 15 x cable diameter
fixed: 5 x cable diameter
Dynamic penetration according to DKE requirement profile PV1-F AK 411.2.3 Appendix F
Tear propagation resistance according to DKE requirement profile PV1-F AK 4112.3 Appendix G
Tear strength and elongation test according to EN 60811
Chemical properties
Weather / UV resistance according to HD 605/A1
Ozone resistance according to EN 50396
Halogen-free according to EN 50267
Fire behavior flame-retardant according to IEC 60332-1-2
Acid and alkali resistance according to EN 60811-2-1 (oxalic acid and caustic soda)