Lapp oil flex © Solar XLR-R 1x4 Wh/BK

Stock: Available (more than 10)
Product number: 8-01-006300
EAN: 4044777179121
google-icon

Google Reviews

4.9

113 Reviews

€1.50*

Oilflex® Solar XLR-R lines are weather, abrasion and UV-resistant photovoltaic lines. These halogen -free, double isolated and networked solar lines are suitable for constant use outdoors for the connection of grounded and undeveloped photovoltaic systems. They are used to wire solar modules with each other, as well as to connect the individual module series and the inverter. The management has been checked by TÜV Rheinland according to 2 PfG 1169/08.2007 (PV1-F) type.

Important product properties:

Line cross -section: 1x4mm
Manufacturer: Lapp cable
Color outdoor insulation: black
Color interior insulation: white

XLR-R solar lines from LAPP can generally be laid in the ground in the ground in the ground laying, if it is ensured that there is no permanent contact with water and waterlogging is removed safely. The laying of the lines in the ground and the correct execution of the cable ditch must correspond to VDE 0100 part 520 or comparable standards in order to prevent damage to the protective tube and the permanent suspension of the cable and lines with penetrating water. Long -term, permanent storage and permanent operation of the lines in or under water is not permitted.

Leadership

1. Head: Fine-wound strands made of tinned Cu wires, according to IEC 60228, class 5
2. Ader insulation: Electron beam network polyolefin co-polymer
3. Outside mantle Electron beam network polyolefin co-polymervour mantle: black or black with red or blue stripes

Electrical Properties

Nominal voltage: U0/U according to IEC AC 600/1000 V DC 900/1500 V
Max. Permissible system voltage: 1.8 KV DC (head/conductor, non -grounded system) in accordance with TÜV 2 PfG 1169/08.2007 Pru? F voltage AC 6.5 kV

Thermal properties

Temperature range determined: -40 ° C to +120 ° C max. Max. Ladder temperature (in accordance with EN 60216-2)
Temperature range stipulated: -40 ° C to +90 ° C ambient temperature TÜV 2 Pfg 1169/08.2007
Flexible laying temperature: max. -25 ° C
Heat pressure resistance in accordance with EN 60811-3-1
Moisten-heating pru? Fung in accordance with EN 60068-2-78 with 85% humidity

Mechanical properties

Minimum bending radius occasionally moved: 15 x cable diameter
Set: 5 x cable diameter
Dynamic penetration according to the DKE requirement profile PV1-F AK 411.2.3 Appendix F
Further tearing resistance according to the DKE requirement profile PV1-F AK 411.2.3 Appendix G
Pru?

Chemical properties

Weather / UV resistance according to HD 605 / A1
Ozone resistance in accordance with EN 50396
Halogen freedom in accordance with EN 50267
Fire behavior flamed according to IEC 60332-1-2
Acid and lye resistance in accordance with EN 60811-2-1 (oxalic acid and sodium hydroxide solution)
Delivery time: 5-6 working days

data sheet

Generally
item number 8-01-006300
Manufacturer Lapp cable
EAN 4044777179121